OptionalatlasesOptionalcapacityThe table's volume capacity, for the volume grid (W63): with a capacity of at least
PROBE_GRID_MIN_VOLUMES the grid is packed at probeGridRow(capacity) and the packed rows run to
its end. Default: no grid (the lookup then walks every volume).
OptionalenabledFalse while capturing: the lookup then returns zero coverage (environment only). Default true.
Atlas slot of the environment, or -1 for none.
OptionalirradianceFirst row of the irradiance block (default: right after capacity volumes).
Last mip of the atlas (roughness 1).
OptionalrefitUpper bound of the re-fit ratio frameIrradiance / probeIrradiance. Default 4.
The atlases of a set whose probes live in several (one per resolution class, D4700), at most PROBE_MAX_ATLASES: each one's last mip and first irradiance slot. Atlas 0 holds the environment slot and its
maxLodshould be the header's. Absent (one atlas): header rows 2 and 3 stay zero, as before.